Current Transducer GO-SME/SP3 series
IP N = 10 … 20 A
Ref: GO 10-SME/SP3, GO 20-SME/SP3
For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between
the primary and the secondary circuit.
Features
Applications
● Hall effect measuring principle
● Small drives
● Galvanic separation between primary and secondary circuit
● HVAC
● Insulated test voltage 2500 V RMS
● Appliances
● Low power consumption
● E-Bikes.
● Extremely low profile
Standards
● Fixed offset & sensitivity
● Delay time 2 µs.
● IEC 61800-5-1: 2007
Special feature
● IEC 60950-1: 2005
● IEC 62109-1: 2010
● Single power supply +3.3 V.
● UL 1577: 2014.
Advantages
Application Domains
● Small size and space saving
● Industrial.
● High immunity to external interference
● High insulation capability
● Low electrical resistance (0.9 mΩ)
● No magnetic hysteresis
● Robust against external fields.
Page 1/9
N°G2.05.13.003.0; N°G2.05.17.003.0
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Absolute maximum ratings
Parameter
Symbol
Unit
Min
Typ
Maximum supply voltage (not entering nonstandard modes)
UC max
V
Maximum primary withstand peak current
ÎP max
A
±200 TA = 25 °C, 1 ms pulse
Maximum electrostatic discharge voltage
(HMB-Human Body Model)
UESD HBM
V
2000 AEC-Q100-002 REV D
Maximum electrostatic discharge voltage
(CDM-Charged Device Model)
UESD CDM
V
500
Maximum output current source
Iout max
mA
25
Maximum output current sink
Iout max
mA
50
Maximum junction temperature
TJ max
°C
150
Symbol
Unit
Value
RMS voltage for AC insulation test, 50 Hz, 1 min
Ud
V
2500
According to IEC 60664-1
RMS voltage for AC insulation test, 60 Hz, 1 min
Ud
V
2500
According to UL 1577
RMS voltage for AC insulation test, 50 Hz, 1 min
Ud
V
2500
According to IEC 60950-1
Impulse withstand voltage 1.2/50 μs
UNi
V
4000
According to IEC 61800-5-1 ,
IEC 62109-1, IEC 60950-1
Partial discharge RMS test voltage (qm < 5 pC)
Ut
V
900
According to IEC 61800-5-1,
IEC 62109-1
Clearance (pri. - sec.)
dCI
Creepage distance (pri. - sec.)
dCp
mm
4
Comparative tracking index
CTI
Maximum supply voltage (not destructive)
Max
Conditions
8
6.5
AEC-Q100-011 REV B
Insulation coordination
Parameter
Application example
Comment
Shortest distance through air
Shortest path along body
600
V RMS
300
Basic insulation according to
IEC 61800-5-1, IEC 62109-1,
IEC 60950-1, CAT II, PD2
UL 1577 Non Optical isolating devices - Component
File # E486776, Vol 1
Single protection, non-optical isolators, 2500 vac insulation
Standards
● UL 1577, Optical Isolators;
● CSA Component Acceptance Service Notice N°. 5 A, Component Acceptance Service for Optocouplers and Related Devices.
Marking
Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under UL’s FollowUp Service. Always look for the Mark on the product.
Page 2/9
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Environmental and mechanical characteristics
Parameter
Symbol
Unit
Min
TA
°C
‒40
125
Ambient storage temperature
TA st
°C
‒55
165
Resistance of the primary @ TA = 25 °C
RP
mΩ
0.9
Thermal resistance, junction to board 1)
Rth JB
k/W
15
t
s
1
Ambient operating temperature
Time constant
Typ
Max
Conditions
To reach steady state
Note: 1) Done on LEM evaluation board PCB 2320.
Block diagram
IP
UC
Voltage
Regulator
Clock
Uref
Reference
Driver
and filter
Amplification and filters
Uout
X
X
Chopping
De-chopping
Calibration stored in
EEPROM
IP
1
Connection diagram
Pin#
A
Name
2
3
4
Function
From 1 to 2
IP+
Input of the primary current
From 3 to 4
IP−
Output of the primary current
5
GND
6
Uref
Reference voltage (output)
7
Uout
Output voltage
8
UC
Supply voltage
Ground
GO-SME
Ip+
Ip+
+Uc
8
Ip+
Uout
+Uc
2
7
Ip-
Uref
Uout
3
6
Ip-
Uref
4
GND
5
B
Ip-
+Uc
1
47nF
47nF
4.7nF
GND
Page 3/9
12November2020/Version 4
C
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
+Uc
+Uc
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Electrical data GO 10-SME/SP3
At TA = ‒40 °C … 125 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Definition of typical, minimum and maximum values
paragraph in page 6).
Parameter
Symbol
Unit
Min
Primary nominal RMS current
IP N
A
Primary current, measuring range
IP M
A
‒25
Supply voltage
UC
V
3.135
Current consumption
IC
Reference voltage (output)
Reference voltage (input)
Typ
Max
Conditions
10
25
3.3
3.465
mA
20
26
Uref
V
1.65
Uref
V
0.5
1.7
Uout ‒ Uref
V
‒1.25
1.25
Output internal resistance
Rout
Ω
Reference internal resistance
Rref
Ω
120
Load capacitance
CL
nF
0
Nominal sensitivity
SN
mV/A
Electrical offset voltage @ IP N = 0
UO E
mV
‒5
5
Electrical offset current referred to IP N
IO E
mA
‒100
100
TA = 25 °C
Temperature coefficient of Uref
TCUref
ppm/K
‒170
170
Uref = 1.65 V
Temperature coefficient of UO E
TCUO E
mV/K
‒0.075
0.075
Temperature coefficient of IO E
TCIO E
mA/K
‒1.5
1.5
Temperature coefficient of S
TCS
ppm/K
‒150
150
Delay time to 90 % of the final output value IP N step
tD 90
µs
2
Delay time to 10 % of the final output value IP N step
tD 10
µs
1.5
Frequency bandwidth ‒3 dB, TA = 25 °C
BW
KHz
300
Noise voltage spectral density
uno
µV/Hz1/2
8
Sensitivity error
εS
%
‒1
1
Linearity error 0 … IP N
εL
% of IP N
‒0.3
0.3
Linearity error 0 … IP M
εL
% of IP M
‒0.6
0.6
Sum of sensitivity and linearity @ IP N, @
TA = 25 °C
εS L
% of IP N
‒1.3
1.3
Sum of sensitivity and linearity @ IP N
@ TA = 85 °C 1)
εS L
% of IP N
‒3.1
3.1
Sum of sensitivity and linearity @ IP N
@ TA = 105 °C 1)
εS L
% of IP N
‒3.7
3.7
Sum of sensitivity and linearity @ IP N @ TA
= 125 °C 1)
εS L
% of IP N
‒4.3
4.3
Output voltage range @ IP M
Notes:
1)
@ 25 °C, Internal ref.
5
200
External reference
Up to 10 kHz
333
6
50
TA = 25 °C, Uout ‒ Uref
@ Uref = 2.5 V
NBW = 1 kHz … 100
kHz
Factory adjustment,
@ 25 °C
TA = 25 °C
Sum of sensitivity and linearity @ T:
εS
L
(TA=)
εS
L 25
TCIO E
+ TCS +
IP N
× TA − 25
Page 4/9
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Electrical data GO 20-SME/SP3
At TA = −40 °C … 125 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Definition of typical, minimum and maximum values
paragraph in page 6).
Parameter
Symbol
Unit
Min
Primary nominal RMS current
IP N
A
Primary current, measuring range
IP M
A
‒50
Supply voltage
UC
V
3.135
Current consumption
IC
Reference voltage (output)
Reference voltage (input)
Typ
Max
Conditions
20
50
3.3
3.465
mA
20
26
Uref
V
1.65
Uref
V
0.5
1.7
Uout ‒ Uref
V
‒1.25
1.25
Output internal resistance
Rout
Ω
Reference internal resistance
Rref
Ω
120
Load capacitance
CL
nF
0
Nominal sensitivity
SN
mV/A
Electrical offset voltage @ IP N = 0
UO E
mV
‒5
5
Electrical offset current referred to IP N
IO E
mA
‒200
200
TA = 25 °C
Temperature coefficient of Uref
TCUref
ppm/K
‒170
170
Uref = 1.65 V
Temperature coefficient of UO E
TCUO E
mV/K
‒0.075
0.075
Temperature coefficient of IO E
TCIO E
mA/K
‒3
3
Temperature coefficient of S
TCS
ppm/K
‒150
150
Delay time to 90 % of the final output value IP N step
tD 90
µs
2
Delay time to 10 % of the final output value IP N step
tD 10
µs
1.5
Frequency bandwidth ‒3 dB, TA = 25 °C
BW
KHz
300
Noise voltage spectral density
uno
µV/Hz1/2
7
Sensitivity error
εS
%
‒1
1
Linearity error 0 … IP N
εL
% of IP N
‒0.3
0.3
Linearity error 0 … IP M
εL
% of IP M
‒0.6
0.6
Sum of sensitivity and linearity @ IP N, @
TA = 25 °C
εS L
% of IP N
‒1.3
1.3
Sum of sensitivity and linearity @ IP N
@ TA = 85 °C 1)
εS L
% of IP N
‒3.1
3.1
Sum of sensitivity and linearity @ IP N
@ TA = 105 °C 1)
εS L
% of IP N
‒3.7
3.7
Sum of sensitivity and linearity @ IP N @
TA = 125 °C 1)
εS L
% of IP N
‒4.3
4.3
Output voltage range @ IP M
Notes:
1)
@ 25 °C, Internal ref.
5
200
External reference
Up to 10 kHz
333
6
25
TA = 25 °C, Uout ‒ Uref
@ Uref = 2.5 V
NBW = 1 kHz … 100
kHz
Factory adjustment,
@ 25 °C
TA = 25 °C
Sum of sensitivity and linearity @ T:
εS
L
(TA=)
εS
L 25
TCIO E
+ TCS +
IP N
× TA − 25
Page 5/9
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Definition of typical, minimum and maximum values
Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values shown
in “typical” graphs.
On the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower
limits and a probability for measured values to lie within this interval.
Unless otherwise stated (e.g. “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that the
probability for values of samples to lie in this interval is 99.73 %.
For a normal (Gaussian) distribution, this corresponds to an interval between ‒3 sigma and +3 sigma. If “typical” values are not
obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to an
interval between ‒sigma and +sigma for a normal distribution.
Typical, maximal and minimal values are determined during the initial characterization of the product.
Page 6/9
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Dimensions (in mm)
Page 7/9
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Leader & Trailer:
Carrier Tape Data:
Plastic Reel Data:
Page 8/9
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
GO-SME/SP3 series
Soldering requirements
MSL3, 260 °C - IPC/JEDEC J-STD-020
Ordering information
Item number
Description
G2.05.13.003.0
GO 10-SME/SP3
G2.05.13.103.0
GO 10-SME/SP3 KIT 5P
G2.05.13.303.0
GO 10-SMS/SP3 SET OF 50 PCS
G2.05.17.003.0
GO 20-SME/SP3
G2.05.17.103.0
GO 20-SME/SP3 KIT 5P
G2.05.17.303.0
GO 20-SME/SP3 SET OF 50 PCS
Package type
Package quantity
Reel
3000
Blister
5
ESD Bag
50
Reel
3000
Blister
5
ESD Bag
50
Page 9/9
12November2020/Version 4
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com